HomeSpec Certified Inspections, Inc. Providing inspections throughout Southwest Florida. Call or text: (941) 270-1349 Fla License # HI959 Become a home inspector in Maryland Re: Sweating air handler Dave Fetty Certified Professional Inspector Florida Home Inspection And Property Services LLC Naples, Marco Island, Ft. Myers, Bonita Springs, Estero, Cape Coral ITC/FLIR Level I Building Investigation Thermographer FL Certified Building Contractor CBC034303 FL Certified Home Inspector HI 391 FL Certified Mold Assessor MRSA 589 Yea, I explained the unit might need more insulation but it was only an educated guess and to get a HVAC tech to confirm and or recommend the fix. Originally Posted by tmiller2 I can not see from here but if you think about what you are asking (what causes condensation) that is your answer the air temp is lowered to dew point and if it is making contact with the outer surface of the AHU it will condense out.
You did not say if the unit was a down flow, a upflow or horizontal flow just that it was hanging from the ceiling. It would ber most helpful to know what area of the furnace has the condensation the coil box, I can not image the return air section having any condensation the temp is to high Serving Gainesville Florida and surrounding areas.Deus solus me iudicare potest Originally Posted by frotteHowever if they restricted the air over the coils as in blocking of some of the registers and or bad or clogged filters that will freeze it up as well. Justin, that just makes too much sense. and your post did not include the phase of the moon! "working together to get-IR-done" Chris Walsh David A. Andersen & Associates Clarksville - Nashville Home Inspector Lic#40 ITC Level III Thermographer Cert#1958 Building Science Thermographer Cert#33784 HVAC Certification EPA Cert#2046620 Were your clients with you during their inspection? I just find it odd people, knowing how long you examined systems, the conditions of the weather outdoors, and everything else short term - would call you back, wanting what exactly?
You're not their land lord, for sure. Is this a common occurrence with Home Inspectors to receive a call back?Cast Iron Bathtubs For Sale Craigslist Personally, it would never haunt me. Yorkie Puppies For Sale In Nj Under 300I would politely tell them they aren't my tenant and there are most likely Professional HVAC businesses that can handle their concerns.Do Cree Led Bulbs Flicker Todd - a couple of things to note; 1) with heat pump air handlers - the cases are insulated throughout / however, air handlers of a furnace / coupled with split AC installation; the case of the AH - furnace does not have an insulated case portion. therefore making the exterior of the case cold. and 2) as one person said above, condensation / dewpoint is the issue.
Much like a cold drink sweats on the outside, so does / will the uninsulated case. But, it is all based on differential temperatures and the humidity of the air on the warm side. What you will learn from How to Fix Sweating Copper Pipes article:one of our readers submitted the question, How to Fix Sweating Copper Pipes - and we will answer her question.a description of the problem with the sweating pipethe name of the copper pipe causing the problem and why it is sweatingthe repair of the sweating copper pipe to stop it from sweatingwhat you need to know about sweating pipes and any moisture problem in your houselots of resource and related links to help you learnFix Sweating Copper PipesHow to Fix Sweating Copper Pipes - Richard, we have an air handler in a finished attic closet. We use the attic for our home office and TV room. I noticed the last time I went in the closet the copper pipes that go into the air handler were sweating and dripping on the floor. It is a wooden floor but I think if this continues it will eventually ruin the floor and possibly the ceiling downstairs.
What can I do to fix this problem of sweating pipes? Does it mean there is a problem with our air conditioner? Will I have to call my HVAC service guy to fix this or is it something I can fix myself? We have used your site for many years to answer questions about our HVAC system. Thanks and I look forward to your reply. Joanna K. Hibernia FLFix Sweating Copper Pipes | AnswerJoanna, You are talking about the suction line that goes into the air handler. Somehow it lost its insulation and is sweating in the closet. The suction line typically operates below the dew point. When you have something that has a temperature less than the dew point temperature then it will sweat. The moisture in the air is condensing. Changing from a vapor to a liquid. A very good example of this is a glass of ice water sitting on the table. The temperature of the glass is so cold it is below the dew point temperature. The glass sweats and leaves a wet spot on the table. Thankfully someone invented coasters to protect wood from cold drinks.
Now we need to invent a coaster for that sweaty copper pipe you have there. Anyhow Joanna, this is something you can fix yourself very easily. Find your local hardware store and ask them for Rubatex pipe insulation. It a black foam insulation. It is better if you get the kind with a split on the side and on the side of the split is a type of adhesive with a protective plastic strip on it. You will trim the length of Rubatex you will need to cover the bare copper pipe and then peel the protective plastic off of the adhesive strip after placing the insulation over the pipe. Line the split up and make sure the adhesive glues the Rubatex split together. You want to create a vapor barrier to keep the humidity out and away from the pipe. That should fix your problem of the sweaty copper pipe.Related Link: An Air Conditioner caused severe water damage (opens in a new window)Wet Dripping Pipes Cause 1Wood to rotWet Dripping Pipes Cause 2Drywall to become waterlogged and eventually crumbleWet Dripping Pipes Cause 3Mold and mildew to grow inside your wallsFix Sweating Copper Pipes |
Health and PreventionIt is important for you to know a few things about this repair to your air conditioner lines:If the pipe has been leaking long enough then it is possible that some of the moisture dripped down the pipe and went into the chase where the pipe runs. Sometimes, especially in new construction, the installer will use the void in the wall as his chase to run the pipes to the condenser. If that moisture got inside the walls it is possible it created a problem with mold and mildew. Mold and mildew loves dark, moist areas.It is important that you only insulate the suction and not the liquid line. The suction line is the bigger of the two pipes that run to your condensing unit. Even the part of the suction line that runs in the chase should be insulated with Rubatex and have a good vapor barrier quality of insulation on it otherwise you get the problem described above in number one. Never insulate the smaller pipe. It should never sweat. If it does sweat it would defy physics.
Related Link: Another problem with an air conditioner and a leak (opens in a new window) If you suspect mold or mildew in your walls then you will have to probably call a professional to look into it. Most HVAC companies in Florida are well aware of these problems as the humidity in Florida is something they have to deal with sometimes. At least the problems that come with high humidity and removing it from a conditioned space.Related Link: Indoor Air Quality in your home or business (opens in a new window)How to Fix Sweating Copper Pipes | HVAC Cooling Repair - ConclusionThere are companies that specialize in water damage and sometimes that includes dealing with the mold and mildew inside closed spaces. I know these companies use a special spray that kills the mold and mildew and prevents it from coming back anytime soon. I know that some molds and mildews are not good for health especially not breathing it every day. I know there are some people with severe allergies to mold and mildew so make sure you protect yourself.